SUP2-PV series surge protector | SUP4-PV | ||
PV DC specific (LEC 6614-1/EN 61643-11) | |||
Pole | 2 pole | 3 pole | |
Electrical Parameter | |||
Classifical test | II | II | |
Uoc max (V DC) | 500 | 900 | |
Uc (V DC) | 500 | 1000 | |
In(8/20)us (KA) | 20 | 20 | |
Imax(8/20)us (KA) | 40 | 40 | |
Up (KV) | 2.0 | 3.8 | |
Remote control and indication | |||
Indication window | |||
Plug-in module | |||
Remote signal contact | |||
Remote signal contact | Max working volt | 250V AC/30V DC | 250V AC/30V DC |
Max working amp 1A (250V/AC) | 1A (250V/AC) | 1A (250V/AC) | |
1A (30V DC) | 1A (30V DC) | 1A (30V DC) | |
Wiring & installation | |||
Wiring capacity(mm2) | Hard wire | 4-25 | 4-25 |
|
Flexible wire | 4-16 | 4-16 |
Stripping length | 10 | 10 | |
Terminal screwa | M5 | M5 | |
Torque(Nm) | Main ciruit | 3.5 | 3.5 |
Remote signal contact | 0.25 | 0.25 | |
Protection class | All profile | IP40 | IP40 |
Connection port | IP20 | IP20 | |
Installation environment | No obvious shock and vibration | ||
Altitude(m) | ≤ 2000 | ≤ 2000 | |
Working temperature | -3.0--+70 | -3.0--+70 | |
Relative humidity | 30%-90% | 30%-90% | |
How to install | Install with H35-7.5/DIN35 stell mounting rail | ||
Size(mm) (W*H*L) | W | 36 | 54 |
H | 90 | 90 | |
L | 67.6 | 67.6 | |
Weight (KG) | 0.25 | 0.38 |
Nominal PV system volt | 600V | 100V | 1200V |
MCOV(UCPV) | 700V DC | 1170V DC | 1200V DC |
Max system discharge Current (8/20us) (Imax) | 40KA | 40KA | 30KA |
Volt protection leve (UP) | ≤ 2.5KV | ≤ 4.0KV | ≤ 4.5KV |
Volt protection Level at 5KA (UP) | ≤ 2.0KV | ≤ 3.5KV | ≤ 4.0KV |
Integrate fuse breaking capacity/interrupting rating | 30KA/1000V DC | 30KA/1000V DC | 30KA/1200V DC |
Technology | Short-circuit interruption (SCI) overcurrent protection | ||
Operating temperature range | -40 to +80 | ||
Nominal discharge current | 12.5KA | ||
Response time (ta) | <25ns | ||
Operating state/fault indication | Green (good) / Red (replace) | ||
Mounting | 35mm DIN Rail per EN 60715 | ||
Degree protection | IP20 | ||
capacity | 3 modules DIN 43880 |
AC SPD | Class C | ||||
Max. continuous voltage Uc | 275 V | 320 V | 420 V/ 440V | ||
pole | 1P 2P 1P+N 3P 3P+N 4P | ||||
Nominal discharge current (8/20μs) In | 20 kA | ||||
Max. discharge current (8/20μs) Imax | 40 kA | ||||
Lightning impulse current (10/350) [N-PE] limp | ≤ 12.5 kA | ||||
Voltage protection level [L-N] Up | 1.0 kV | 1.5kV | 1.6kV | ||
Voltage protection level [N-PE] Up | ≤ 1.2kV | ||||
Response time tA | ≤ 25 ns | ||||
Max. back-up fuse | 125 A gl/gG | ||||
Short-circuit withstand current | 25kA/50Hz | ||||
Operating temperature range TU | -40°C+80°C | ||||
Cross-sectional area (min.) | 1.5 mm2 solid / flexible | ||||
Cross-sectional area (max.) | 35 mm2 stranded / 25 mm2 flexible | ||||
Mounting on | 35 mm DIN rail acc. To EN 60715 | ||||
Degree of protection | IP 20 | ||||
Housing material | Thermoplastic; extinguishing degree UL 94 V-0 | ||||
Remote signaling contact (floating switch) | Yes (optional accessory) | ||||
Switch capacity | AC: 250V/0.5A; 125V/3 A | ||||
Cross-sectional area for remote signaling terminals | Max. 1.5 mm2 solid / flexible |
Product Model | Product Model | SUP1 D,C,B | |||||||||||||||
The number of poles | 1P , 2P , 1P+N, 3P , 3P+N, 4P | ||||||||||||||||
Rated working voltage Un(V) | 230/400 | ||||||||||||||||
nominal discharge current (8/20μs)kA | 10 | 20 | 30 | 60 | |||||||||||||
Max discharge current | 20 | 40 | 60 | 100 | |||||||||||||
Max Continuous Operating Voltage | 275 | 320 | 440 | 460 | 275 | 320 | 420 | 460 | 275 | 320 | 420 | 460 | 275 | 320 | 420 | 460 | |
Protection level | <1.0 | <1.4 | <1.6 | <1.8 | <1.2 | <1.6 | <1.8 | <2.0 | <1.5 | <1.8 | <2.0 | <2.2 | <1.6 | <1.8 | <2.2 | <2.4 | |
Prepose fuse | 25AGL | 50AGL | 80AGL | 80AGL | |||||||||||||
Response time (ns) | <25 | ||||||||||||||||
Leak current 75% Uc 1mA | <20μA | ||||||||||||||||
Testing classification | II | ||||||||||||||||
Protection class | IP20 | ||||||||||||||||
Ambient temperature limited | -40°C~+80°C | ||||||||||||||||
Material of insulation sheath | PBT/PA66 | ||||||||||||||||
Fire Retardant level UL94 | VO | ||||||||||||||||
Installation method | 35mm standard electric rail | ||||||||||||||||
Outside color | red | ||||||||||||||||
Recommended fuse or breaker A | 40~63 | ||||||||||||||||
Sectional area of the linked power line (mm ) |
Phase/Null line | 1.5~3.5 hard wire | |||||||||||||||
Ground lead | 1.5~3.5 double color | ||||||||||||||||