AC DC voltmeter analog ammeter analog voltmeter
1. Specification of ammeter for through current: 0.1A 0.5A 1A 1.5A 3A 5A 10A 15A 20A 25A 30A 40A 50A 60A
75A 100A,
2. Specification of ammeter for transformation ratio: The meters should be used with a current transformer of
Which primary current is 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A 120A 150A...10KA and external
Secondary current 1A or 5A. As long as overload rate and the incoming current keep the same, dial scales
Of all types in this series can be exchanged ye remain the accuracy.
3. Overload rate of ammeters: 1. Non-overload 2.1.2times 3.2times 4.5times.
4. Specification of voltmeters for through voltage: 30V 50V 75V 100V 120V 150V 200V 250V 300V 400V 450V
500V 600V.
5. Specification of voltmeters for transformation ratio: The meters should be used with a voltage transformer of
Which primary voltage is 400V 450V 500V 600V 1000V 1500V 2000V 3000V 5000V...450KV and external
Secondary voltage 100V.
6. Overload rate of voltmeters: 1. Non-overload 2.1.2times.
7. Product performance: All the meters are equipped with pure white silk- screen printing dial scale. The movement is made of intensive PBT plastics and high-performance magnetic materials so that it is vibration-resistant and heat-resistant. The case is made of ordinary ABS plastics of flame retardant ABS plastics, of which the resistant
Temperature can be up to 85° C. The base is made of PC plastics or flame retardant PC plastics, of
Which the resistant temperature can be up to 120° C. The resistant voltage is higher than 2000V.
The resistant voltage is higher than 2000V. This kind of meter is easy to install with high-strengthen plastics grip piece by screwing down the nut so that the meter is of high immobility.
8. Principles of measurement and the features: Each electromagnetic meter consists of a magnet
Coil with a static sheet iron inside and a moving sheet iron with a tractive balance spring.
When current flows through the magnet coil, magnetic field appears. Under such circumstance, the
Static and the moving sheet irons are magnetized simultaneously and remain the same polarity.
According to the theory that the same polarities repel each other, repulsive force between the two
Irons makes the pointer deflect. When the torque and the restoring torque keep a balance, the static
And the moving sheet irons are magnetized simultaneously and remain the same polarity.
According to the theory that the same polarities repel each other, repulsive force between the two
Irons makes the pointer deflect. When the torque and the restoring torque keep a balance, the pointer
On the moving iron will point to a scale mark, which is the measured value.
9. The ellectromagnetic meters can be used for AC circuits under ordinary circumstance as well as for
DC circuit instructed with TRMS. The structure of this kind of meters is simple, yet the accuracy is high,
As well, they can be used for 50/60Hz circuit. Special frequency should be marked out when the order is placed.
Name |
precision |
normal specification |
remark |
AC ammeter |
A |
1.5 |
0.5-50A |
can be directly connected |
A |
1.5 |
10/5A-800/5A |
secondary current passed by
current transformer |
KA |
1.5 |
1KA-10KA |
secondary current passed by
current transformer |
AC voltmeter |
V |
1.5 |
10V-600V |
can be directly connected |
KV |
1.5 |
1KV-35KV |
100V secondary voltage passed by voltage transformer |
DC ammeter |
µ A mA |
2.5 |
50 μ A-500 μ A 1mA-500mA |
can be directly connected |
A |
1.5 |
1A-15A |
can be directly connected |
A |
1.5 |
15A-750A |
outer attached shunt 75mV 60mV 50mV
|
KA |
1.5 |
1KA-3KA |
outer attached shunt 75mV 60mV 50mV
|
DC voltmeter |
V |
1.5 |
3V-600V |
can be directly connected |
KV |
1.5 |
1KV-3KV |
outer attached resistance value |
Hz meter |
Hz |
2.5 |
45-55HZ 55-65HZ |
36V.100V.127V.220V.380V |
Power meter |
KW.VAR |
2.5 |
100V 380V 380-380KV |
100V secondary voltage passed by voltage ; Secondary current passed by current
transformer 5-10KA/5A |
cos φ meter |
cos φ |
2.5 |
COS φ =0.5-1-0.5 |
100V/5A 220V/5A 380V/5A |