kwh meter electrical meter energy meter power meter
Single-phase Two-wire Electronic DIN-rail Active Energy Meter (1Pole, LCD Display)
APPLICATION | ||||||||||||||||||||||||||||||||||
single phase two wire electronic DIN-rail active energy meter. The meter is used to measure 50Hz or 60Hz active energy consumption from single phase two wire AC electricity net. The features of small size and DIN-rail mounting make it suitable for installation in distribution boards and small standard enclosures. The meter is widely used in the office buildings, shopping malls, residences, airports and metro,etc. | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
FUNCTIONS AND FEATURES | ||||||||||||||||||||||||||||||||||
35mm standard DIN rail installation or front board setting, complying with standard DIN EN50022. one pole width. LCD 6+1 digits display (999999.1kWh) by without backlight source common LCD.May select white backlight source LCD display, or clients defined. Standard configuration one port of pulse output passive (polarity),complying with standard IEC62053-31 and DIN43864. Single direction measures single phase two wire active power consumption. It is nothing with direction of the flow of load current, complying with standard IEC62053-21,IEC62052-11. Adopts high reliable and long-life electric components, high overload, do not need to calibrate for long-term operation. Directly connect operation. Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install. | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
TECHNICAL PARAMETERS | ||||||||||||||||||||||||||||||||||
|
APPLICATION | ||||||||||||||||||||||||||||||||||
three phase three wire electronic DIN-rail active energy meter,cyclometer display. The meter is used to measure 50Hz or 60Hz active energy consumption from three phase three wire AC electricity net. The features of small size and DIN-rail mounting make it suitable for installation in distribution boards and small standard enclosures. The meter is widely used in the office buildings, shopping malls, residences, airports and metro, etc. | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
FUNCTIONS AND FEATURES | ||||||||||||||||||||||||||||||||||
35mm standard DIN rail installation,complying with standard DIN EN50022.Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves. Seven poles width. Cyclometer 5+1 digits display (99999.9kWh),may select 6+1 digits (999999.9kWh)display. Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive (nonpolarity),complying with standard IEC62053-31 and DIN 43864. LED indicates respectively power-supply,impulse,and communication,etc. Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse. Single direction three components measure three phase three wire active energy consumption.It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11. Direct connect operation or through CT or PT & CT. Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install;May select extended terminal cover. | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
TECHNICAL PARAMETERS | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
|
APPLICATION | ||||||||||||||||||||||||||||||||||
three phase three wire electronic DIN-rail active energy meter,LCD display. The meter is used to measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net. The features of small size & DIN-rail mounting make it suitable for installation in distribution boards and small standard enclosures. The meter is widely used in the office buildings, shopping malls, residences, airports and metro,etc. | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
FUNCTIONS AND FEATURES | ||||||||||||||||||||||||||||||||||
35mm standard DIN rail installation,complying with standard DIN EN50022.Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves. Seven poles width. LCD 6+1 or 5+2 display without backlighting;May select with white backlighting, and there is maintenance-free battery used for display when the power-supply cut off. Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive (nonpolarity),complying with standard IEC62053-31 and DIN 43864. LED indicates respectively power-supply,impulse,and communication,etc. Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse. Single direction three components measure three phase three wire active energy consumption.It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11. Direct connect operation or through CT or PT & CT. Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install;May select extended terminal cover. | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
TECHNICAL PARAMETERS | ||||||||||||||||||||||||||||||||||
|
APPLICATION | ||||||||||||||||||||||||||||||||||
three phase four wire electronic DIN-rail active energy meter, cyclometer display. The meter is used to measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net. The features of small size and DIN-rail mounting make it suitable for installation in distribution boards and small standard enclosures. The meter is widely used in the office buildings, shopping malls, residences, airports and metro, etc. | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
FUNCTIONS AND FEATURES | ||||||||||||||||||||||||||||||||||
35mm standard DIN rail installation,complying with standard DIN EN50022. Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves. Seven-pole width. Cyclometer 5+1 digits display (99999.9kWh),may select 6+1 digits display. Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive (nonpolarity),complying with standard IEC62053-31 and DIN 43864. LED indicates phase, impulse, reverse, etc. Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse. Single direction three components measure three phase four wire active energy consumption. It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11. May select two components measure three phase three wire active energy or two phase three wire active energy. Direct connect operation or through CT or PT & CT. Standard configuration short terminal cover,which is helpful to reduce installation space and make it convenient to install;May select extended terminal cover. | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
TECHNICAL PARAMETERS | ||||||||||||||||||||||||||||||||||
|
APPLICATION | |||||||||||||||||||||||||||||||||||
three phase four wire electronic DIN-rail active energy meter,LCD display. The meter is used to measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net. The features of small size & DIN-rail mounting makes it suitable for installation in distribution boards and small standard enclosures. The meter is widely used in the office buildings,shopping malls,residences,airports and metro,etc. |
|||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
FUNCTIONS AND FEATURES | |||||||||||||||||||||||||||||||||||
35mm standard DIN rail installation,complying with standard DIN EN50022.Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves. Seven poles width. LCD 6+1 or 5+2 display without backlighting;May select with white backlighting, and there is maintenance-free battery used for display when the power-supply cut off. Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive (nonpolarity),complying with standard IEC62053-31 and DIN 43864. LED indicates phase-line,impulse,reverse,etc. Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse. Single direction three components measure three phase four wire active energy consumption.It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11. May select two components measure three phase three wire active energy or two phase three wire active energy. Direct connect operation or through CT or PT & CT. Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install; May select extended terminal cover. |
|||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
TECHNICAL PARAMETERS | |||||||||||||||||||||||||||||||||||
|