Basic Info
  • Model NO.: DDM
  • Installation: DIN Rail
  • Electric Equipment: Single-phase
  • Power Meter Connection: Terminal
  • Type: Energy Meter
  • Customized: Customized
  • Model Number: Electricity Meter
  • Measuring Range: 20A 25A 30A 40A 60A 80A 100A
  • Supply Voltage: 220V-360V AC
  • Phase: Single Phase or Three Phase
  • Isntallation: 35mm
  • Specification: CE
  • HS Code: 9030900090
  • Display: Digital
  • Usage: Multi-Functional Energy Meter, Standard Electric Energy Meter
  • Theory: Electronic Meter
  • Measured Signal: Continuous Wave
  • Certification: RoHS, CE
  • Brand Name: Suntree/OEM
  • Display Type: Digital Only
  • Accuracy Class: 1.0
  • Operating Temperature: -25--+55
  • Measure: V, a, Kw, Cos, Hz,
  • Trademark: SUNTREE/oem
  • Origin: Zhejiang Wenzhou
Product Description

kwh meter electrical meter energy meter power meter

 Single-phase Two-wire Electronic DIN-rail Active Energy Meter (1Pole, LCD Display)


APPLICATION
single phase two wire electronic DIN-rail active energy meter.
The meter is used to measure 50Hz or 60Hz active energy consumption from single phase two wire AC electricity net. 
The features of small size and DIN-rail mounting make it suitable for installation in distribution boards and 
small standard enclosures.
The meter is widely used in the office buildings, shopping malls, residences, airports and metro,etc.

 
FUNCTIONS AND FEATURES
35mm standard DIN rail installation or front board setting, complying with standard DIN EN50022.
one pole width.
LCD 6+1 digits display (999999.1kWh) by without backlight source common LCD.May select white backlight   source LCD display, or clients defined.
Standard configuration one port of pulse output passive (polarity),complying with standard IEC62053-31 and DIN43864.
Single direction measures single phase two wire active power consumption. It is nothing with direction of the flow of load current, complying with standard IEC62053-21,IEC62052-11.
Adopts high reliable and long-life electric components, high overload, do not need to calibrate for long-term operation.
Directly connect operation.
Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install.

 
TECHNICAL PARAMETERS 
Accuracy Class 1.0
Rated voltage 220VAC, 230VAC, 240VAC, etc.
Operation voltage range   Un±20%
Insulation capabilities AC voltage withstand 2kV for 1 minute; Impulse voltage withstand 6kV - 1.2/50μs waveform.
Rated current range 5(20)A , 5(25)A , 5(30)A,5(32)A,etc.
Operation current range 0.05Ib~ Imax
Starting current  0.004Ib
Rated frequency 50Hz or 60 Hz
Internal power consumption Voltage circuit ≤1.0W 5VA; Current circuit ≤1VA(Ib)
Impulse valence Ra 0,5 or 1.0 Wh/imp 
Interface Optical coupler (SO corresponding to DIN43864)
Max.operation temperature -40°C ~ +80°C 
Max.storage temperature -45°C ~ +85°C
Relative humidity ≤85
Dimension 17.5mm * 76.5mm * 90mm     
Weight Approx. 90g
*Please advise us if you need any different specifications,we can make according to your special requirements.



Kwh Meter Electrical Meter Energy Meter Power Meter
Three-phase Three-wire Electronic DIN-rail Active Energy Meter (7-Pole, Cyclometer Display)

APPLICATION
three phase three wire electronic DIN-rail active energy meter,cyclometer display.
The meter is used to measure 50Hz or 60Hz active energy consumption from three phase three wire AC electricity net.
The features of small size and DIN-rail mounting make it suitable for installation in distribution boards and small standard enclosures.
The meter is widely used in the office buildings, shopping malls, residences, airports and metro, etc.

 
FUNCTIONS AND FEATURES
35mm standard DIN rail installation,complying with standard DIN EN50022.Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
Seven poles width.
Cyclometer 5+1 digits display (99999.9kWh),may select 6+1 digits (999999.9kWh)display.
Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive   
(nonpolarity),complying with standard IEC62053-31 and DIN 43864.
LED indicates respectively power-supply,impulse,and communication,etc.
Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse.
Single direction three components measure three phase three wire active energy consumption.It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11.
Direct connect operation or through CT or PT & CT.
Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install;May select extended terminal cover.

 
TECHNICAL PARAMETERS
Accuracy Class 1.0
Rated voltage(VAC) 3*57.5/110,  3*110/200,  3*220/380,  3*230/400,  3*240/415,etc.
Operation voltage range Un±20%
Insulation capabilities AC voltage withstand 2kV for 1 minute;Impulse voltage withstand 6kV - 1.2/50μs waveform
Rated current(A) 1.5(6), 5(30), 10(60), 20(80), 30(100),etc.
Operation current range 0.05Ib~ Imax
Starting current 0.004Ib
Rated frequency 50Hz or 60Hz
Internal power consumption Voltage circuit ≤1.0W 5VA;   Current circuit ≤1VA(Ib)
Impulse valence Ra 0.5 or 1.0 Wh/imp
Interface optical coupler (SO corresponding to DIN 43864)
Temperature Range Normal operation temperature: -35ºC--+70ºC
Extreme operation temperature: -40ºC--+75ºC
Storage Temperature: -45ºC--+85ºC
Relative humidity ≤ 85%
Service Life More than 10 years
Dimension 125mm x 88mm x 73mm
Weight Approx 650g
*Please advise us if you need any different specifications, we can make according to your special requirements.

 



Three-phase Three-wire Electronic DIN-rail Active Energy Meter (7-Pole, LCD Display)
APPLICATION
 three phase three wire electronic DIN-rail active energy meter,LCD display.
The meter is used to measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net.
The features of small size & DIN-rail mounting make it suitable for installation in distribution boards and small standard enclosures.
The meter is widely used in the office buildings, shopping malls, residences, airports and metro,etc.

 
FUNCTIONS AND FEATURES
35mm standard DIN rail installation,complying with standard DIN EN50022.Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
Seven poles width.
LCD 6+1 or 5+2 display without backlighting;May select with white backlighting, and there is maintenance-free battery used for display when the power-supply cut off.
Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive (nonpolarity),complying with standard IEC62053-31 and DIN 43864.
LED indicates respectively power-supply,impulse,and communication,etc.
Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse.
Single direction three components measure three phase three wire active energy consumption.It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11.
Direct connect operation or through CT or PT & CT.
Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install;May select extended terminal cover.

 
TECHNICAL PARAMETERS
Accuracy Class 1.0
Rated voltage(VAC) 3*57.5/110,  3*110/200,  3*220/380,  3*230/400,  3*240/415,etc.
Operation voltage range Un±20%
Insulation capabilities AC voltage withstand 2kV for 1 minute;Impulse voltage withstand 6kV - 1.2/50μs waveform
Rated current(A) 1.5(6), 5(30), 10(60), 20(80), 30(100),etc.
Operation current range 0.05Ib~ Imax
Starting current 0.004Ib
Rated frequency 50Hz or 60Hz
Internal power consumption Voltage circuit ≤1.0W 5VA;   Current circuit ≤1VA(Ib)
Impulse valence Ra 0.5 or 1.0 Wh/imp
Interface optical coupler (SO corresponding to DIN 43864)
Temperature Range Normal operation temperature: -35ºC--+70ºC
Extreme operation temperature: -40ºC--+75ºC
Storage Temperature: -45ºC--+85ºC
Relative humidity ≤ 85%
Service Life More than 10 years
Dimension 125mm x 88mm x 73mm
Weight Approx 650g
*Please advise us if you need any different specifications,we can make according to your special requirements.


Three-phase Four-wire Electronic DIN-rail Active Energy Meter (7-Pole, Cyclometer Display)
APPLICATION
three phase four wire electronic DIN-rail active energy meter, cyclometer display.
The meter is used to measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net.
The features of small size and DIN-rail mounting make it suitable for installation in distribution boards and small standard enclosures.
The meter is widely used in the office buildings, shopping malls, residences, airports and metro, etc.

 
FUNCTIONS AND FEATURES
35mm standard DIN rail installation,complying with standard DIN EN50022. Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
Seven-pole width.
Cyclometer 5+1 digits display (99999.9kWh),may select 6+1 digits display.
Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive (nonpolarity),complying with standard IEC62053-31 and DIN 43864.
LED indicates phase, impulse, reverse, etc.
Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse.
Single direction three components measure three phase four wire active energy consumption. It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11.
May select two components measure three phase three wire active energy or two phase three wire active energy.
Direct connect operation or through CT or PT & CT.
Standard configuration short terminal cover,which is helpful to reduce installation space and make it convenient to install;May select extended terminal cover.

 
TECHNICAL PARAMETERS
Accuracy Class 1.0
Rated voltage(VAC) 3*57.5/110,  3*110/200,  3*220/380,  3*230/400,  3*240/415,etc.
Operation voltage range Un±20%
Insulation capabilities AC voltage withstand 2kV for 1 minute;Impulse voltage withstand 6kV - 1.2/50μs waveform
Rated current(A) 1.5(6), 5(30), 10(60), 20(80), 30(100),etc.
Operation current range 0.05Ib~ Imax
Starting current 0.004Ib
Rated frequency 50Hz or 60Hz
Internal power consumption Voltage circuit ≤1.0W 5VA;   Current circuit ≤1VA(Ib)
Impulse valence Ra 0.5 or 1.0 Wh/imp
Interface optical coupler (SO corresponding to DIN 43864)
Temperature Range Normal operation temperature: -35ºC--+70ºC
Extreme operation temperature: -40ºC--+75ºC
Storage Temperature: -45ºC--+85ºC
Relative humidity ≤ 85%
Service Life More than 10 years
Dimension 125mm x 88mm x 73mm
Weight Approx 650g
*Please advise us if you need any different specifications, we can make according to your special requirements.



Three-phase Four-wire Electronic DIN-rail Active Energy Meter (7-Pole, LCD Display)
APPLICATION  
three phase four wire electronic DIN-rail active energy meter,LCD display.
The meter is used to measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net.
The features of small size & DIN-rail mounting makes it suitable for installation in distribution boards and small standard enclosures.
The meter is widely used in the office buildings,shopping malls,residences,airports and metro,etc.
 

 
 
FUNCTIONS AND FEATURES  
35mm standard DIN rail installation,complying with standard DIN EN50022.Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
Seven poles width.
LCD 6+1 or 5+2 display without backlighting;May select with white backlighting, and there is maintenance-free battery used for display when the power-supply cut off.
Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive (nonpolarity),complying with standard IEC62053-31 and DIN 43864.
LED indicates phase-line,impulse,reverse,etc.
Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse.
Single direction three components measure three phase four wire active energy consumption.It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11.
May select two components measure three phase three wire active energy or two phase three wire active energy.
Direct connect operation or through CT or PT & CT.
Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install; May select extended terminal cover.
 

 
 
TECHNICAL PARAMETERS  
Accuracy Class 1.0
Rated voltage(VAC) 3*57.5/110,  3*110/200,  3*220/380,  3*230/400,  3*240/415,etc.
Operation voltage range Un±20%
Insulation capabilities AC voltage withstand 2kV for 1 minute;
Impulse voltage withstand 6kV - 1.2/50μs waveform
Rated current(A) 1.5(6), 5(30), 10(60), 20(80), 30(100),etc.
Operation current range 0.05Ib~ Imax
Starting current 0.004Ib
Rated frequency 50Hz or 60Hz
Internal power consumption Voltage circuit ≤1.0W 5VA;   Current circuit ≤1VA(Ib)
Impulse valence Ra 0.5 or 1.0 Wh/imp
Interface optical coupler (SO corresponding to DIN 43864)
Temperature Range Normal operation temperature: -35ºC--+70ºC
Extreme operation temperature: -40ºC--+75ºC
Storage Temperature: -45ºC--+85ºC
Relative humidity ≤ 85%
Service Life More than 10 years
Dimension 125mm x 88mm x 73mm
Weight Approx 650g
*Please advise us if you need any different specifications,we can make according to your special requirements.




SINGLE PHASE TWO WIRE DIN-RAIL WATT-HOUR METER
Kwh Meter Electrical Meter Energy Meter Power Meter



THREE PHASE FOURWIRE DIN-RAILWATT-HOUR METER
Kwh Meter Electrical Meter Energy Meter Power Meter