CJX2-0910 LC1-D09 AC 230V electrical contactor
LC1-D AC contactor
Application
1)LC1-D series AC Contactor
is suitable for using in the circuits up to the rated voltage 660V AC50Hz or 60Hz,
rated current up to 95A, for making, breaking, frequently starting & controllingthe AC motor.
2)Combined with the auxiliary contact block, timer delay & machine-interlockingdevice etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter.With the thermal relay, it is combined into the electromagnetic starter.
3)The product conforms to IEC60947-4-1 CE stardand.
Standard Control Circuit Voltage
Volts |
24 |
42 |
48 |
110 |
220 |
230 |
240 |
380 |
400 |
415 |
440 |
500 |
600 |
50Hz |
B5 |
D5 |
E5 |
F5 |
M5 |
P5 |
U5 |
Q5 |
V5 |
N5 |
R5 |
S5 |
Y5 |
60Hz |
B6 |
D6 |
E6 |
F6 |
M6 |
- |
U6 |
Q6 |
- |
- |
R6 |
- |
- |
50/60Hz |
B7 |
D7 |
E7 |
F7 |
M7 |
P7 |
U7 |
Q7 |
V7 |
N7 |
R7 |
- |
- |
LC1-D AC contactor Technical Data
Type |
LC1-D09 |
LC1-D12 |
LC1-D18 |
LC1-D25 |
LC1-D32 |
LC1-D40 |
LC1-D50 |
LC1-D65 |
LC1-D80 |
LC1-D95 |
Rated working current (A) |
AC3 |
9 |
12 |
18 |
25 |
32 |
40 |
50 |
65 |
80 |
95 |
AC4 |
3.5 |
5 |
7.7 |
8.5 |
12 |
18.5 |
24 |
28 |
37 |
44 |
Standard power ratingsof 3-phase motors 50/60Hz in category AC-3 |
220/230V |
2.2 |
3 |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
25 |
380/400V |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
415V |
4 |
5.5 |
9 |
11 |
15 |
22 |
25 |
37 |
45 |
45 |
500V |
5.5 |
7.5 |
10 |
15 |
18.5 |
22 |
30 |
37 |
55 |
55 |
660/690V |
5.5 |
7.5 |
10 |
15 |
18.5 |
30 |
33 |
37 |
45 |
55 |
Rated heat current (A) |
20 |
20 |
32 |
40 |
50 |
60 |
80 |
80 |
125 |
125 |
Electrical life |
AC3 (x104) |
100 |
100 |
100 |
100 |
80 |
80 |
60 |
60 |
60 |
60 |
AC4 (x104) |
20 |
20 |
20 |
20 |
20 |
15 |
15 |
15 |
10 |
10 |
Mechanical life (x104) |
1000 |
1000 |
1000 |
1000 |
800 |
800 |
800 |
800 |
600 |
600 |
Number of the contacts |
3P+NO |
3P+NC+NO |
3P+NC |
LC1-D AC contactor Dimensioned
Type |
A |
B |
C |
D |
E |
a |
b |
|
LC1-D09~12 |
47 |
76 |
82 |
113 |
133 |
34/35 |
50/60 |
4.5 |
LC1-D18 |
47 |
76 |
87 |
118 |
138 |
34/35 |
50/60 |
4.5 |
LC1-D25 |
57 |
86 |
95 |
126 |
146 |
40 |
48 |
4.5 |
LC1-D32 |
57 |
86 |
100 |
131 |
151 |
40 |
48 |
4.5 |
LC1-D40~65 |
77 |
129 |
116 |
145 |
165 |
40 |
100/110 |
6.5 |
LC1-D80~95 |
87 |
129 |
127 |
175 |
195 |
40 |
100/110 |
6.5 |
LC1-DN AC contactor
Application
1)LC1-DN series AC contactor is suitable for frequency 50/60Hz, rated insulation voltage up to1000V,
rated operation current 9~150A under AC-3 duty. It is mainly used for making/breaking electric circuits at a long distance & for frequent
starting/stopping & controlling AC Motors.
2)It isused in combination with thermal relay to compose a magnetic motor starter.
3)The products com-ply with IEC60947-4-1 standard.
Standard Control Circuit Voltage
Volts |
24 |
42 |
48 |
110 |
220 |
230 |
240 |
380 |
400 |
415 |
440 |
500 |
600 |
50Hz |
B5 |
D5 |
E5 |
F5 |
M5 |
P5 |
U5 |
Q5 |
V5 |
N5 |
R5 |
S5 |
Y5 |
60Hz |
B6 |
D6 |
E6 |
F6 |
M6 |
- |
U6 |
Q6 |
- |
- |
R6 |
- |
- |
50/60Hz |
B7 |
D7 |
E7 |
F7 |
M7 |
P7 |
U7 |
Q7 |
V7 |
N7 |
R7 |
- |
- |
LC1-DN AC contactor Technical Data
Type |
LC1-DN09 |
LC1-DN12 |
LC1-DN18 |
LC1-DN25 |
LC1-DN32 |
LC1-DN38 |
LC1-DN40 |
Rated working current Ie (A) AC-3 Ue≤440V |
9 |
12 |
18 |
25 |
32 |
38 |
40 |
Rated hear current Ith (A) |
25 |
25 |
32 |
40 |
50 |
50 |
60 |
Rated insulation voltage Ui (V) |
690 |
690 |
690 |
690 |
690 |
690 |
1000 |
Rated operating voltage Ue (V) Max |
690 |
690 |
690 |
690 |
690 |
690 |
1000 |
Rated operational power in AC-3 Pe (KW) |
220/230V |
2.2 |
3 |
4 |
5.5 |
7.5 |
9 |
11 |
380/400V |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
18.5 |
415/440V |
4 |
5.5 |
9 |
11 |
15 |
18.5 |
22 |
500V |
5.5 |
7.5 |
10 |
15 |
18.5 |
18.5 |
22 |
660/690V |
5.5 |
7.5 |
10 |
15 |
18.5 |
18.5 |
30 |
Rated operational power in AC-4 Pe (KW) |
220/230V |
1.5 |
1.5 |
2.2 |
3 |
4 |
4 |
4 |
380/400V |
2.2 |
3.7 |
4 |
5.5 |
7.5 |
7.5 |
9 |
415/440V |
2.2 |
3 |
3.7 |
5.5 |
7.5 |
7.5 |
9/11 |
500V |
3 |
4 |
5.5 |
7.5 |
9 |
9 |
11 |
660/690V |
4 |
5.5 |
7.5 |
10 |
11 |
11 |
15 |
Frequency of operation (I/h) |
|
1200 |
1200 |
1200 |
1200 |
1000 |
1000 |
1000 |
Electrical endurance (x104) |
AC-3 |
100 |
100 |
100 |
100 |
80 |
80 |
80 |
AC-4 |
20 |
20 |
20 |
20 |
20 |
20 |
15 |
Mechanical endurance (x106) |
|
15 |
15 |
15 |
15 |
15 |
15 |
6 |
Operating voltage range of coil |
Close voltage:(0.85~1.1)Us Open voltage:(20%~75%)Us |
Power consumption of coil (VA) |
Atracting |
7 |
7 |
7 |
7 |
7 |
7 |
20 |
Starting |
70 |
70 |
70 |
70 |
70 |
70 |
200 |
Rated insulation voltage of auxitiary contacts (V) |
690 |
690 |
690 |
690 |
690 |
690 |
690 |
690 |
Conventional thermal current of auxitiary contacts (A) |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
Auxitiary contacts speecification |
AC-15:360VA DC-13:33W |
Type |
LC1-DN50 |
LC1-DN65 |
LC1-DN80 |
LC1-DN95 |
LC1-DN115 |
LC1-DN150 |
Rated working current Ie (A) AC-3 Ue≤440V |
50 |
65 |
80 |
95 |
115 |
150 |
Rated hear current Ith (A) |
80 |
80 |
125 |
125 |
200 |
200 |
Rated insulation voltage Ui (V) |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
Rated operating voltage Ue (V) Max |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
Rated operational power in AC-3 Pe (KW) |
220/230V |
15 |
18.5 |
22 |
25 |
30 |
40 |
380/400V |
22 |
30 |
37 |
45 |
55 |
75 |
415/440V |
25/30 |
37 |
45 |
45 |
59 |
80 |
500V |
30 |
37 |
55 |
55 |
75 |
90 |
660/690V |
33 |
37 |
45 |
45 |
80 |
100 |
Rated operational power in AC-4 Pe (KW) |
220/230V |
5.5 |
7.5 |
7.5 |
9 |
9 |
11 |
380/400V |
11 |
11 |
15 |
15 |
18.5 |
22 |
415/440V |
11 |
11/15 |
15 |
15 |
18.5 |
22 |
500V |
15 |
18.5 |
22 |
22 |
30 |
37 |
660/690V |
18.5 |
22 |
25 |
25 |
30 |
45 |
Frequency of operation (I/h) |
|
1000 |
1000 |
750 |
750 |
750 |
750 |
Electrical endurance (x104) |
AC-3 |
60 |
60 |
60 |
60 |
60 |
60 |
AC-4 |
15 |
15 |
15 |
15 |
15 |
15 |
Mechanical endurance (x106) |
|
6 |
6 |
4 |
4 |
4 |
4 |
Operating voltage range of coil |
Close voltage:(0.85~1.1)Us Open voltage:(20%~75%)Us |
Power consumption of coil (VA) |
Atracting |
20 |
20 |
20 |
20 |
22 |
22 |
Starting |
200 |
200 |
200 |
200 |
300 |
300 |
Rated insulation voltage of auxitiary contacts (V) |
690 |
690 |
690 |
690 |
690 |
690 |
690 |
Conventional thermal current of auxitiary contacts (A) |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
Auxitiary contacts speecification |
AC-15:360VA DC-13:33W |
LC1-DN AC contactor Dimensioned
Type |
09 |
12 |
18 |
25 |
32 |
38 |
40 |
50 |
65 |
80 |
95 |
115 |
150 |
b |
76.6 |
76.6 |
76.6 |
76.6 |
76.6 |
76.6 |
127 |
127 |
127 |
127 |
127 |
158 |
158 |
c |
87 |
87 |
87 |
94 |
94 |
94 |
116 |
116 |
116 |
123.8 |
123.8 |
132 |
132 |
LC1-F AC contactor
Application
LC1-F series
AC contactor is applicable in the circuits up to the rated voltage 1000V AC 50Hz or 60Hz,rated
curent 780A, for long distance breaking circuit and frequently starting or control the motor.
It also can be used for the control of distribution circuits of rated current from 200A TO 1600A. LC1-F AC contactor Technical Data
Type |
LC1-F115 |
LC1-F150 |
LC1-F185 |
LC1-F225 |
LC1-F265 |
LC1-F330 |
LC1-F400 |
LC1-F500 |
LC1-F630 |
Rated operation current (A) |
AC-3 |
115 |
150 |
185 |
225 |
265 |
330 |
400 |
500 |
630 |
Standard power ratings of 3-phase motors AC-3(KW) |
220V |
30 |
40 |
55 |
63 |
75 |
100 |
110 |
147 |
200 |
380V |
55 |
75 |
90 |
110 |
132 |
160 |
200 |
250 |
335 |
415V |
59 |
80 |
100 |
110 |
140 |
180 |
200 |
280 |
375 |
440V |
59 |
80 |
100 |
110 |
140 |
200 |
250 |
295 |
400 |
500V |
75 |
90 |
110 |
129 |
160 |
200 |
257 |
335 |
400 |
660V |
80 |
100 |
110 |
129 |
160 |
200 |
280 |
335 |
450 |
1000V |
65 |
65 |
100 |
100 |
147 |
160 |
185 |
335 |
450 |
phone:008615067704943
name:Alan
#jTlxhpgjSTips {Z-INDEX: 999999999; POSITION: absolute; WIDTH: 56px; HEIGHT: 24px; LEFT: 1342177.27em}#jTlxhpgjSTips A {LINE-HEIGHT: 24px; MARGIN: -32px 0px 0px; PADDING-LEFT: 23px; WIDTH: auto; DISPLAY: block; BACKGROUND: url(http://mat1.gtimg.com/www/sogou/sogou_tips_v1.png) no-repeat 0px 0px; HEIGHT: 24px; COLOR: #000; FONT-SIZE: 12px; TEXT-DECORATION: none; _position: relative}#jTlxhpgjSTips A:hover {BACKGROUND-POSITION: 0px -34px; COLOR: #45a1ea}